3rd party equipment integration (BACnet and WAGO). Daikins optimum solution with top comfort. YORK CUSTOM AIR HANDLING UNITS 2,000200,000 CFMe a tin g. INTEGRATED SOLUTIONS TO OPTIMIZE YOUR BUILDING’S PERFORMANCE AIR SYSTEMS YORK® AIR HANDLING UNITS, COILS & FANS YORK SOLUTION AIR HANDLING UNITS 2,000-120,000 CFM Indoor and outdoor, 2 foam double-wall panels with external frame, variable aspect, flexible factory-packaged controls.

Comprehensive management and system functions are available: Alarm management Time scheduling Trends Access protection Type summary System controllers System-Controller for the integration of KNX, M-Bus, Modbus or SCL over BACnet/LonTalk System-Controller for the integration of KNX, M-Bus, Modbus or SCL over BACnet/IP Option modules Up to 800 data points SCL: up to 1000 data points, M- Bus and Modbus: up to 2000 data points) Type PXC001.D PXC001-E.D Type PXA40-RS1 PXA40-RS2 Equipment combinations PXC001.D PXC001-E.D PXA40-RS1 PXA40-RS2 Interfaces KNX X - Serial RS232 X - Serial RS485 X - Network functions Integration KNX 2000 DP - Integration M-Bus 250 DP 800 DP 2000 DP Integration Modbus 250 DP 800 DP 2000 DP Integration SCL 250 DP 800 DP 1000 DP Option modules are "hot-pluggable" PXA40- option modules can be plugged and unplugged when the automation station is operating. They are freely programmable. Functionality as freely programmable system controllers for standard or proprietary protocol applications Functions The system controllers provide the infrastructure to hold and execute the system and application specific functions. In the automation level using BACnet/LonTalk or BACnet/IP Mapping and monitoring of third-party disciplines as HVAC, light, SPS etc. Integration platforms and system controllers for third-party devices and systems via KNX, Modbus, M-Bus and other protocols into the automation level via BACnet System controllers for the integration of Desigo RXB/RXL room controllers Native BACnet devices with communication via BACnet/LonTalk or BACnet/IP BTL label (BACnet communications passed the BTL test) Comprehensive management and system functions (alarm management, time scheduling, trends, remote management, access protection etc.) Supports operation via local or network-compatible operator units PXM CM1N9223en_06 Building Technologies1 RS485, BACnet MS/TP 2 RS485, MODBUS RTU 3 BACnet IP 4 MODBUS TCP/IP 5 DualNet serial communications, IP and RS485 6 JCI N2 7 Siemens P1 8 LonWorks D Analog Output 0 No analog output 1 Single (1) isolated analog output 2 Four (4) isolated analog outputs (Not available when C5) E Auxiliary Pulse InputsUse The system controllers support the integration of Desigo RXB/RXL room controllers as well as third-party devices and systems via KNX, Modbus or M- Bus etc.

1 2 3 4 5 RS232/RS485 KNX CLA CLB RX TX RX TX SERVICE RUN FAULT LOW BATT COMM INFO SERVICE RS485 RS232 KNX HMI/TOOL CE - CE + TOOL SERVICE 6 7 8 9 10 HMI 1 Plastic housing 2a Front cover 2b PXM40-RS. Our chillers serve HVAC systems that deliver the right temperature, humidity and ventilation for the space, but they also help minimize operating costs with superior energy efficiency levels, low sound levels and with minimal environmental impact.Ordering Product number Stock number Designation PXC001.D S55372-C113 System controllers ( BACnet/LonTalk) PXC001-E.D S55372-C114 System controllers (BACnet/IP) PXA40-RS1 S55372-C115 Option module RS1 PXA40-RS2 S55372-C116 Option module RS2 Mechanical design The compact construction enables the devices to be mounted on a standard mounting rail. Review specific job warranty requirements with owner, and overall project requirements.Each building has its own unique set of conditions required to ensure the health, comfort and productivity of its occupants. If equipment warranties are critical to the owner, discuss the extensive CFC-E warranty compared to industry standards and competition. 2 / 10The below warranties are specific to the CFC-E product. The functionality disappears approx.1 minute after unplugging.

LED indicators Communication RS232/RS485: RX (Green) : TX (Yellow) KNX: RX (Green) TX (Yellow) Service (Red) The other LEDs have the following meaning: Service pin LED Color Activity Function RUN Green Continuously ON Continuously OFF Power OK No power FAULT Red Continuously OFF Continuously ON Rapid flashing OK Fault Firmware missing / corrupt LOW BATT Red Continuously OFF Continuously ON Battery OK Battery empty replace! COMM Red Continuously ON Continuously OFF Flashing Connection to switch OK No connection to switch Communication INFO Red Freely programmable SERVICE (Ethernet, PXC001- E.D) Red SERVICE Red (LonTalk, PXC001.D) Continuously OFF Continuously ON Flashing Flashing per wink command *) Continuously OFF Continuously ON Flashing Flashing per wink command *) OK No connection to switch No IP address configured Physical identification of system controller after receipt of wink command LONWORKS node is configured Faulty LONWORKS chip, or service pin currently depressed LONWORKS node is not configured Physical identification of system controller after receipt of wink command *) Wink command pattern: 21s 9222z02 5 Hz 5 Hz 2s 1s 2s 1s Service pin Identification of the system controller in the IP network or LONWORKS network See "Commissioning". 750-263 07/2008 Clearfire Condensing Boiler Model CFC Gas High Efficiency Boiler Operation, Service, and Parts Manual Table Of Contents CLEAVER-BROOKS MILWAUKEE, WISCONSIN ANSI STANDARD Z21.13b-2004 CSA 4.9b-2004 LOW PRESSURE BOILER ANSI STANDARD Z21.13b-2005 CSA 4.9b-2005Terminal blocks The terminal blocks are removable for easy wiring. 2b 9223z16 3 / 10Manual Part No.

The power supply, LonTalk, RS485 and KNX connections have plug-in screw terminal blocks. 4 / 10Mounting The devices can be snapped onto standardized rails. Depending on the bus topology, a 120 Ohm resistor must be connected.

Data visible on the network may also be edited with an operator unit PXM20 / PXM20-E (BACnet / LonTalk or BACnet / IP). Use the PX Design tool in XWP for setting the control parameters and the configuration data. Load plant operating program Setting parameters and configurations The plant operating program is downloaded using the CFC from XWP locally via the automation station's RJ45 interface or via the network (BACnet/IP or BACnet/LonTalk). Commissioning In order to prevent equipment damage and/or personal injuries always follow local safety regulations and the required safety standards. Option module can be fitted on the device. Instead of the front cover a PXA40-RS.

Cfc-E 2000 Bacnet Integration Guide Download Key Is

Variant via V24: If the Force Firmware Download Key is pressed for approx. For unique identification in the network (BACnet/IP or BACnet/LonTalk), press the Service button with a long, pointed object or send a wink command to the appropriate system controller (service LED blinks). The network addresses are configured with XWP. Wiring test Network connection Force Firmware Download Use the Point Test Tool.

Restart Press the Reset button to force a restart 5 / 10Position of buttons and batteries Lithium Lithium Service Note The KNX programming pin is situated next to the KNX terminal block and the KNX tool plug Maintenance Battery life The real time clock is backed by a lithium battery type CR2032 Life span without charge: 10 years. For details see the Firmware Download Tool User's guide, CM110626. Prerequisite: A node setup of the controller has been conducted and no application is loaded or it was deleted in the CFC by clear/reset (communication settings remain which would not be the case when restart erasing by pressing the reset key). IP variant: (for PXC001-E.D, significantly faster than via V24) Press the Force Firmware Download key for 5 seconds (without hitting the reset button). The system controller waits briefly for the signal to activate the FWLoader and then starts the system controller.

cfc-e 2000 bacnet integration guide

Note the special disposal notes on Li batteries. Insert new battery correctly (+ / ). The battery can be removed indefinitely as long as the unit has power. Replacing the battery STOP Caution! To change the battery, remove the front cover.

The relevant national legal rules are to be adhered to. Disposal The devices are classified as waste electronic equipment in terms of the European Directive 2012/19/EU (WEEE) and should not be disposed of as unsorted municipal waste. Flash ROM memory can be easily updated on the plant, when a new firmware version is available. Firmware upgrades Firmware and operating system stored in non-volatile Flash ROM.

Disposal: Seal battery terminals with tape. Do not short circuit, charge, disassemble, dispose of in fire, heat above 100 C, or expose to water. Lithium batteries: May catch fire, explode or leak. Observe all local and applicable laws.

10 A Operating data Processor Motorola Power PC MPC885 Storage 64MB SDRAM / 32MB FLASH (96MB total) Data backup in event of power failure Battery Backup of realtime clock Battery operation (cumulative): 10 years Lithium CR2032 (field replaceable) Battery backup for SDRAM 1 x FR6/AA Lithium (field replaceable) Without load: 10 years Battery operation (cumulative): min. 13 A Characteristic B, C, D according to EN 60898 or Power source with current limitation of max. 10 A or Circuit breaker max.